Methodology development for SiC sensor signal modelling in the nuclear reactor radiation environments
PBN-AR
Instytucja
Wydział Energetyki i Paliw (Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie)
Książka
Tytuł książki
ANIMMA 2013 [Dokument elektroniczny]. the third international conference on Advancements in Nuclear Instrumentation Measurement Methods and their Applications : Marseille, June 23–27, 2013
Data publikacji
2013
ISBN
978-147991047-2
Wydawca
IEEE
Publikacja
Główny język publikacji
EN
Tytuł rozdziału
Methodology development for SiC sensor signal modelling in the nuclear reactor radiation environments
Rok publikacji
2013
Strony (od-do)
1--7
Numer rozdziału
Identyfikator DOI
Liczba arkuszy
0.5
Hasło encyklopedyczne
Autorzy
(liczba autorów: 2)
Słowa kluczowe
EN
Monte Carlo simulation
neutron and gamma-ray detection
radiation transport
SiC sensor
spectroscopic measurements
spectrum unfolding
Konferencja
Indeksowana w Scopus
tak
Indeksowana w Web of Science Core Collection
tak
Liczba cytowań z Web of Science Core Collection
Nazwa konferencji (skrócona)
ANIMMA 2013
Nazwa konferencji
3rd International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications
Początek konferencji
2013-06-23
Koniec konferencji
2013-06-27
Lokalizacja konferencji
Marseile
Kraj konferencji
FR
Lista innych baz czasopism i abstraktów w których była indeksowana
INSPEC
Streszczenia
Język
EN
Treść
This paper deals with SiC detector simulation methodology for signal formation by neutrons and induced secondary radiation as well as its inverse interpretation. The primary goal is to achieve the SiC capability of simultaneous spectroscopic measurements of neutrons and gamma-rays for which an appropriate methodology of the detector signal modelling and its interpretation must be adopted. The process of detector simulation is divided into two basically separate but actually interconnected sections. The first one is the forward simulation of detector signal formation in the field of the primary neutron and secondary radiations, whereas the second one is the inverse problem of finding a representation of the primary radiation, based on the measured detector signals. The applied methodology under development is based on the Monte Carlo description of radiation transport and analysis of the reactor physics. The methodology of SiC detector signal interpretation will be based on the existing experience in neutron metrology developed in the past for various neutron and gamma-ray detection systems. Since the novel sensors based on SiC are characterised by a new structure, yet to be finally designed, the methodology for particle spectroscopic fluence measurement must be developed while giving a productive feed back to the designing process of SiC sensor, in order to arrive at the best possible design.