Effects of Intra-Aortic Balloon Pump Timing on Baroreflex Activities in a Closed-Loop Cardiovascular Hybrid Model
PBN-AR
Instytucja
Instytut Biocybernetyki i Inżynierii Biomedycznej im. Macieja Nałęcza Polskiej Akademii Nauk
Informacje podstawowe
Główny język publikacji
EN
Czasopismo
ARTIFICIAL ORGANS
ISSN
0160-564X
EISSN
1525-1594
Wydawca
WILEY-BLACKWELL
DOI
URL
Rok publikacji
2013
Numer zeszytu
3
Strony od-do
237-247
Numer tomu
37
Liczba arkuszy
Słowa kluczowe
EN
Intra-aortic balloon pump;Baroreceptors;Balloon timing;Hybrid model
Open access
Tryb otwartego dostępu
Inne
Wersja tekstu w otwartym dostępie
Wersja opublikowana
Licencja otwartego dostępu
Inna
Czas opublikowania w otwartym dostępie
Razem z publikacją
Data udostępnienia w sposób otwarty
Streszczenia
Język
angielski
Treść
Despite 50 years of research to assess the intra-aortic balloon pump (IABP) effects on patients' hemodynamics, some issues related to the effects of this therapy are still not fully understood. One of these issues is the effect of IABP, its inflation timing and duration on peripheral circulation autonomic controls. This work provides a systematic analysis of IABP effects on baroreflex using a cardiovascular hybrid model, which consists of computational and hydraulic submodels. The work also included a baroreflex computational model that was connected to a hydraulic model with a 40-cm3 balloon. The IABP was operated at different inflation trigger timings (0.14 to 0.31s) and inflation durations (0.050.45s), with time of the dicrotic notch being taken as t=0. Baroreflex-dependent parametersafferent and efferent pathway activity, heart rate, peripheral resistance, and venous tonewere evaluated at each of the inflation trigger times and durations considered. Balloon early inflation (0.09s before the dicrotic notch) with inflation duration of 0.25s generated a maximum net increment of afferent pathway activity of 10%, thus leading to a decrement of efferent sympathetic activity by 15.3% compared with baseline values. These times also resulted in a reduction in peripheral resistance and heart rate by 4 and 4.3% compared with baseline value. We conclude that optimum IABP triggering time results in positive effects on peripheral circulation autonomic controls. Conversely, if the balloon is not properly timed, peripheral resistance and heart rate may even increase, which could lead to detrimental outcomes.