Does the air condition system in busses spread allergic fungi into driver space?
PBN-AR
Instytucja
Instytut Medycyny Pracy im. prof. dr. med. Jerzego Nofera
Informacje podstawowe
Główny język publikacji
EN
Czasopismo
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH (30pkt w roku publikacji)
ISSN
0944-1344
EISSN
1614-7499
Wydawca
SPRINGER HEIDELBERG
DOI
URL
Rok publikacji
2018
Numer zeszytu
5
Strony od-do
5013–5023
Numer tomu
25
Identyfikator DOI
Liczba arkuszy
Słowa kluczowe
EN
Buses
Cars
Air-condition system
Ventilation system
Occupational exposure
Drivers
Mold
Fung
Open access
Tryb otwartego dostępu
Inne
Wersja tekstu w otwartym dostępie
Wersja opublikowana
Licencja otwartego dostępu
Creative Commons — Uznanie autorstwa-Niekomercyjne
Czas opublikowania w otwartym dostępie
Razem z publikacją
Streszczenia
Język
En
Treść
The aim of this study was to establish whether the air-conditioning system in buses constitutes an additional source of indoor air contamination with fungi, and whether or not the fungi concentration depends on the period from the last disinfection of the system, combined with replacement of the cabin dust particle filter. The air samples to fungi analysis using impact method were taken in 30 buses (20 with an air-conditioning system, ACS; 10 with a ventilation system, VS) in two series: 1 and 22 weeks after cabin filter replacement and disinfection of the air-conditioning system. During one test in each bus were taken two samples: before the air-conditioning or ventilation system switched on and 6 min after operating of these systems. The atmospheric air was the external background (EB). After 1 week of use of the system, the fungi concentrations before starting of the ACS and VS system were 527.8 and 1053.0 cfu/m3, respectively, and after 22 weeks the concentrations were 351.9 and 1069.6 cfu/m3, respectively. While in the sample after 6 min of ACS and VS system operating, the fungi concentration after 1 week of use was 127.6 and 233.7 cfu/m3, respectively, and after 22 weeks it was 113.3 and 324.9 cfu/m3, respectively. Results do not provide strong evidence that air-conditioning system is an additional source of indoor air contamination with fungi. A longer operation of the system promoted increase of fungi concentration in air-conditioned buses only.
Cechy publikacji
oryginalny artykuł naukowy
Inne
System-identifier
PX-5aba1e38d5de4c910b6cbcf0