Localization of E-M interference sources in air-insulated substation using VHF/UHF antenna arrays
PBN-AR
Instytucja
Wydział Elektrotechniki, Automatyki, Informatyki i Inżynierii Biomedycznej (Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie)
Książka
Tytuł książki
Elektroenergetika 2017 [Dokument elektroniczny]. proceedings of the 9\textsuperscript{th} international scientific symposium on Electrical power engineering : Stará Lesná, Slovak Republic, September 12–14, 2017
Data publikacji
2017
ISBN
978-80-553-3195-9
Wydawca
Technical University
Publikacja
Główny język publikacji
EN
Tytuł rozdziału
Localization of E-M interference sources in air-insulated substation using VHF/UHF antenna arrays
Rok publikacji
2017
Strony (od-do)
301--305
Numer rozdziału
Link do pełnego tekstu
Identyfikator DOI
Liczba arkuszy
0.4
Hasło encyklopedyczne
Słowa kluczowe
EN
transmission lines
substations
E-M pulses
antenna detection
E-M sources localization
Konferencja
Indeksowana w Scopus
tak
Indeksowana w Web of Science Core Collection
tak
Liczba cytowań z Web of Science Core Collection
Nazwa konferencji (skrócona)
EE 2017
Nazwa konferencji
Elektroenergetika 2017: 9\textsuperscript{th} international scientific symposium on Electrical power engineering
Początek konferencji
2017-09-12
Koniec konferencji
2017-09-14
Lokalizacja konferencji
Stará Lesná
Kraj konferencji
SK
Lista innych baz czasopism i abstraktów w których była indeksowana
Streszczenia
Język
EN
Treść
The demand for high reliability of electricity supply, which is commonly required nowadays, forces the need for diagnostic tests and continuous monitoring of the proper functioning of electrical power equipment. Various test and measurement methods are used in the diagnosis of high-voltage insulating systems. Their selection depends on the construction materials and the design of tested objects. An important group of methods used in diagnostics are measurements using antenna detection of electromagnetic interferences. The presented work deals with the detection and localization of E-M pulse sources caused by partial discharges generated in the air-insulated high voltage transmission systems. Defects occurring in overhead transmission lines and in equipment installed in power substations, which are characterized by local increasing of the electric field strength over the critical value, result in generation of partial discharges in various forms (corona, surface discharges, and internal discharges). Formed as a result E-M pulses of a very short rise times and a narrow widths can be used to detection and location of insulating systems defects by broadband detection of disturbances in VHF/UHF bands. The paper presents an analysis of the EM pulse sources location in air-insulated substations using basic antenna array systems. This is illustrated by the results of laboratory measurements collected with selected directional antenna detection systems used for E-M disturbance detection.